HIPHOTONICS Cat.6 UTP Network Cable is a high-performance unshielded twisted-pair copper cable designed for structured cabling systems, enterprise networks, data centers, IP surveillance, and other Ethernet applications.
Operating up to 250 MHz, Cat.6 UTP cabling is designed for reliable Gigabit Ethernet transmission and can also support higher-speed applications depending on the cable construction, channel length, and overall system configuration. Standard Cat.6 constructions commonly use four twisted pairs and are specified under ANSI/TIA-568.2-D and ISO/IEC 11801 requirements.
HIPHOTONICS offers a range of Cat.6 UTP cable configurations to meet different installation, performance, environmental, and cost requirements.
0755-27662758
sales@hiphotonics.com
Cat.6 UTP Cable Product Range
Our Cat.6 UTP cable series can be supplied in different constructions, conductor sizes, jacket materials, and packaging formats.
| Model / Type | Conductor | Jacket | Typical Application |
|---|---|---|---|
| Cat.6 UTP 23AWG Solid | Solid Bare Copper | PVC / LSZH | Structured Cabling / Data Center |
| Cat.6 UTP 24AWG Solid | Solid Bare Copper | PVC / LSZH | Enterprise LAN / General Networking |
| Cat.6 UTP 24AWG Stranded | Stranded Copper | PVC / LSZH | Flexible Network Connections |
| Cat.6 UTP 26AWG | Stranded Copper | PVC / LSZH | Space-Saving Installations |
| Cat.6 UTP 28AWG Slim | Stranded Copper | PVC / LSZH | High-Density Cabling |
| Cat.6 UTP 30/32AWG Slim | Stranded Copper | PVC / LSZH | Short Patch Connections / High-Density Racks |
Actual available specifications can be customized according to project requirements.
The 23AWG Cat.6 UTP Solid Copper Cable is designed for permanent structured cabling installations where stable electrical performance and mechanical strength are required.
The larger conductor provides low DC resistance and is suitable for longer horizontal cable runs and high-performance network infrastructure.
Typical applications:
A typical 23AWG Cat.6 UTP construction uses four pairs of solid bare copper conductors and can be manufactured with PVC or LSZH jackets.
The 24AWG Cat.6 UTP Solid Copper Cable provides a balance between transmission performance, installation flexibility, and overall cable size.
It is one of the commonly used configurations for Cat.6 structured cabling. Typical commercial products use 24AWG solid copper conductors, 250 MHz bandwidth, and 305 m reel-in-box packaging.
Recommended for:
The 24AWG Stranded Cat.6 UTP Cable is designed for applications requiring greater flexibility than solid-conductor horizontal cable.
The stranded construction makes the cable easier to bend and route, making it particularly suitable for equipment connections and flexible network cabling.
Typical applications:
The 26AWG Cat.6 UTP Cable provides a smaller cable profile while maintaining Cat.6 network performance requirements according to the selected construction.
Its reduced diameter can simplify cable routing and improve cable management in installations where space is limited.
Typical applications:
The 28AWG Cat.6 UTP Slim Cable is designed for high-density network environments where conventional cable diameter may create cable congestion.
Its smaller profile provides improved flexibility and easier cable management around switches, patch panels, and other network equipment.
Advantages include:
The 30/32AWG Cat.6 UTP Slim Cable is designed for short-distance and high-density equipment connections.
The slim construction requires less space and can make it easier to manage large numbers of connections inside network cabinets and data centers.
For example, commercial Cat.6 slim patch cables are available in 30AWG constructions with U/UTP shielding and 250 MHz performance.
Typical applications:
HIPHOTONICS Cat.6 UTP cables can be supplied with different jacket materials according to the application environment.
PVC is a cost-effective solution for general indoor network installations and is widely used in commercial and residential structured cabling.
LSZH (Low Smoke Zero Halogen) cable is designed for environments where reduced smoke and halogen emissions are required, such as commercial buildings, public facilities, transportation infrastructure, and data centers.
Depending on the required construction, cables can also be specified with different flame-retardant ratings.
Cat.6 UTP cable is typically designed for operation up to 250 MHz and supports 1000BASE-T Gigabit Ethernet applications.
Depending on the specific cable design and complete channel configuration, Cat.6 cabling may also support higher-speed Ethernet applications over limited distances. Therefore, the final network performance should be evaluated based on the complete cabling system rather than the cable alone.
HIPHOTONICS Cat.6 UTP Network Cable is suitable for:
Cat.6 UTP cables are commonly used for 1000BASE-T and PoE applications, with some constructions designed to meet relevant IEEE PoE requirements.
| Parameter | Specification |
|---|---|
| Product | Cat.6 UTP Network Cable |
| Category | Category 6 |
| Shielding | U/UTP |
| Number of Pairs | 4 Pairs / 8 Conductors |
| Bandwidth | Up to 250 MHz |
| Conductor | Bare Copper |
| Conductor Type | Solid / Stranded |
| Conductor Size | 23 / 24 / 26 / 28 / 30 / 32 AWG |
| Impedance | 100 Ω |
| Insulation | HDPE |
| Jacket | PVC / LSZH |
| Cable Diameter | According to selected model |
| Standard | ANSI/TIA-568.2-D / ISO/IEC 11801 |
| Ethernet Application | 1000BASE-T and other supported applications |
| PoE | Available according to cable construction |
| Length | Customized |
| Cable Color | Customized |
| Packaging | 305m Box / Reel / Customized |
| OEM / ODM | Available |
Final specifications, electrical performance, flame rating, and PoE capability depend on the selected model and construction.
HIPHOTONICS supports customized Cat.6 UTP cable solutions for distributors, system integrators, telecom operators, and structured cabling projects.
Customers can specify:
With multiple Cat.6 UTP configurations available, HIPHOTONICS can provide a suitable balance between transmission performance, installation flexibility, cable density, material cost, and project requirements.
Contact HIPHOTONICS for Cat.6 UTP cable datasheets, samples, OEM specifications, and volume quotations.
Wechat/WhatsApp: +86 130 7568 1698
Tel: +86 0755-27662758
E-mail: sales@hiphotonics.com
Add:D6 Building, Chuangzhao Industrial Park, Kengzi Street, Pingshan District,Shenzhen,China